Lucent Technologies 8.2 Manuale Utente

Pagina di 1707
DEFINITY ECS Release 8.2
Administrator’s Guide  
555-233-506  
Issue 1
April 2000
Screen reference 
473
Administered Connection 
17
7401D phone with 7400B or 8400B data module
7403D/7405D/7407D/7410D/7434D phone with DTDM or 7400B or 
8400B data module
7404D or 7406D phone
510D personal terminal
515 BCT, 615 BCT, or 715 BCT terminal
PC/switch connection
ISDN-BRI Line circuit pack connections, including:
7500 data module
7505D/7506D/7507D phone with ADM
Destination
Used to route the AC to a desired endpoint. Enter the address of the destination 
access or data endpoint. This endpoint is the terminating party of the AC and need 
not be local to the switch on which the AC is assigned. The entry must be 
consistent with the local switch’s dial plan (that is, the first digits are assigned as 
an extension, feature access code, or trunk access code, or DDD Number). If a 
local extension is entered, it must be assigned to either an access or data endpoint. 
Abbreviated Dialing entries may be used in this field.
Valid entries 
Usage
Assigned access endpoint/data 
module extension
The endpoint must be local to the switch on 
which the AC is administered. Nonsignaling 
DS1 trunk or analog tie trunk. 
Valid entries
Usage
Digits 
0
 to 
9
Up to 36 characters
(star)
#
 (pound)
~p
Pause 
~w
Wait for dial tone
~m
Mark
~s
Start suppressing display of the digits being outpulsed
~W
Wait indefinitely for dial tone. Only use this if network 
response time is more than 30 seconds