Screen reference 
728
IP Trunk Configuration Manager 
17
Telephony Advanced dialog box
Use the Telephony Advanced dialog box to adjust additional telephony 
parameters. 
The Telephony Advanced dialog box contains the following parameters:
Maximum Digits to 
Be Collected
Allows you to set the maximum number of digits that the IP trunk 
application will accept from the switch for an outgoing call.
If this value is less than the number of digits actually forwarded by 
the PBX, the calls will not go through.
!
CAUTION:
Set this field no higher than the maximum length of the digit 
string the switch sends. Otherwise, the IP trunk application 
waits several seconds for additional digits and users experience 
delays.
Valid values: 
0
 to 
30
Advanced
Displays the Telephony Advanced dialog box, where you can set 
additional telephony parameters. 
Parameters
Description
Ring Count 
10 
to
 32767
Allows you to set the number of rings before the DEFINITY ECS 
application hangs up because of a No Answer message.
First Digit Time Out
2000
 to 
600,000
Allows you to set the first digit time-out interval in milliseconds for 
the DEFINITY ECS application.
Inter Digit Time 
Out
2000
 to 
600,000
Allows you to set the inter digit time-out interval in milliseconds, 
which sets the time of arrival of subsequent dialed digits from the 
user.
Wink Wait Time
1000
 to 
600,000
Allows you to set the maximum time to wait for the far end to wink 
for an outgoing call. Set to 0 if no wink is expected.
Continued on next page
Parameter
Description
Continued on next page