Lucent Technologies Release 7 Manuale Utente

Pagina di 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-485
DID-TRK (Direct Inward Dial Trunk) 
9
Notes:
See also the preceding section on trunk problems without errors or alarms.
a. This condition occurs when the tone detector times out waiting for digits. 
Change wink/immediate-start parameter to wink/immediate-start and 
rotary/tone-dial parameters.
1. Verify trunk administered wink/immediate-start parameter.
2. Test trunk using BUTT set.
3. Refer problem to CO.
b. Rotary dial before wink 
 This condition occurs when the CO starts 
dialing before the PBX sends wink on a wink-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
2. Refer problem to CO.
c. Rotary dial too early 
 This condition occurs when the CO starts dialing 
too soon after seizure on an immediate-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
2. Refer problem to CO.
d. Rotary dial pulse during wink 
 This condition occurs when the CO 
sends rotary dial digits too soon after seizure on a wink-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
769
Any
Port Diagnostic 
(#35)
MIN/ WRN
2
ON
test port 
UUCSSpp r 3
1025
Looparound and 
Conference (#33)
MIN/ WRN
2
ON
test port 
UUCSSpp l r 3
1281
NPE Crosstalk (#6)
MIN/ WRN
2
ON
test port 
UUCSSpp l r 3
1537
Any
Port Diagnostic 
(#35)
MAJ/ MIN/ 
WRN
2
OFF
test port 
UUCSSpp r 3
1793(m)
57489
None
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2.
Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
Table 9-199.
DID Trunk Error Log Entries  — Continued
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
Continued on next page