Lucent Technologies Release 7 Manuale Utente

Pagina di 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-1597
SYS-PRNT (System Printer) 
9
Error Log Entries and Test to Clear Values
Notes:
a. The System Printer Link has been busied out.
b. A failure was encountered while attempting to set up the System Printer 
Link. This attempt could have been initiated by either Report Scheduler 
software or by link maintenance during automatic link retry or as a result of 
a Link Retry Test (#215) request. The Aux Data field indicates the 
following:
Refer to the preceding section ‘‘Procedures for Restoring the System 
Printer Link f
or recommended maintenance strategy.
c. The SYS-PRNT was interrupted for one of the following reasons:
The cable to the SYS-PRNT output device is disconnected
The SYS-PRNT output device is powered off
The data extension to which the SYS-PRNT output device connects 
has been busied out
Internal software error
Table 9-601.
SYS-PRNT Maintenance Error Log Entries
Error 
Type
Aux Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear 
Value
0
0
Any
Any
Any
test sp-link
18 (a)
0
busyout sp-link
WARNING
OFF
release sp-link
257(b)
1, 3 4, 5, 6
Link Retry Test (#215)
MINOR/
1
 
WARNING
1.
Minor alarms may be downgraded to Warning alarms based on the value used in the set
options
 command.
OFF
test sp-link l
513 (c)
0
None
MINOR
OFF
test sp-link
1
No system port available. Refer to PDATA-PT for explanation.
3, 4
Time-out during setup attempt. Most likely due to problem with physical 
link or printer status.
5
Internal system error. Most likely temporary/sporadic failure.
2, 6
The data module the printer is trying to use is busy with another call. Use 
the Status data module command to determine when the port is 
available for testing.