June 1999
Maintenance Object Repair Procedures 
9-1780
TONE-BD (Tone-Clock Circuit Pack) 
9
Manual PPN Tone-Clock Interchange
In a PPN with more than one Tone-Clock circuit pack, the intention is to assure 
that the one considered most healthy is active at any given time. 
This is 
independent of the SPE Duplication strategy, in the sense that the active 
Tone-Clock circuit pack need not change with an interchange of SPE carriers. 
Rather, except for the effect of the manual intervention discussed earlier, 
Tone-Clock interchanges occur only as a result of changes in the health of 
Tone-Clock circuit packs, as perceived by maintenance software. When both 
Tone-Clock circuit packs are equally healthy, no preference is given to one over 
the other, regardless of which SPE carrier is active.
It is possible to manually control Tone-Clock interchanges in three ways.
1. The standby Tone-Clock circuit pack may be made unavailable for most 
purposes by using the busyout tone-clock UUC command. Such a 
Tone-Clock may not be selected with console commands, nor with normal 
maintenance software activities, until it has been made available again 
with the restore tone-clock UUC command.
NOTE:
busyout tone-clock is not allowed for active Tone-Clock circuit 
packs.
2. The SPE processor lock switches may be used to force a particular SPE to 
be active. 
This method overrides all other Tone-Clock interchange 
controls. If there is a Tone-Clock circuit pack in the same carrier as the 
active SPE, it will become active, regardless of its health. If the Tone-Clock 
circuit pack in the selected SPE was in the 
busyout state (see item 1 
above), it will automatically be released and made active. While the lock 
switches are set for a particular carrier, 
no manual intervention or software 
error detection will cause an interchange of Tone-Clocks; the Tone-Clock 
circuit pack in the standby SPE carrier can never become active. If there is 
no Tone-Clock circuit pack in the selected SPE at the time the switches are 
set, but one is later installed, the system will interchange to it regardless of 
its health. If the Tone-Clock circuit pack is removed from an SPE while the 
switches are set, 
no interchange will occur; the system will have no active 
tone-clock. When the lock switches are restored to the neutral position, a 
tone clock interchange will occur only if the standby Tone-Clock circuit 
pack is healthier than the active one.
3. A particular Tone-Clock circuit pack can be made active by issuing the set 
tone-clock UUC [override] command. If the Tone-Clock to be made 
active is less healthy than the currently active one, no interchange will 
occur unless the override option is specified; without it a message will 
inform the user that it is required.
Once a Tone-Clock circuit pack is made active by the set tone-clock UUC 
command, it will stay active until either the set tone-clock UUC command 
is issued again to make the other circuit pack active, or until a fault occurs 
in the active Tone-Clock circuit pack, which causes the system to 
interchange Tone-Clocks.