Maintenance Object Repair Procedures 
9-16
ADX8D-PT (AUDIX Digital Port) 
9
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy port or link. This is an off-board problem 
that is detected by the port circuit. If this problem exists, replace the 
circuit pack (see caution at the beginning of this section). Once the 
problem is resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the 
voice port. When an error with the link is detected, an on-board counter is 
incremented. Also see Note (a).
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. You can release the port via the 
release port UUCSSpp command.
Table 9-6.
DEFINITY AUDIX Digital Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
40987
None
WARNING
OFF
1(b)
1 to 
20
None
WARNING
OFF
15(c)
Any
None
18(d)
0
busyout port 
UUCSSpp
WARNING
OFF
release port UUCSSpp
23(e)
0
None
WARNING
OFF
130(f)
None
WARNING
ON
test port UUCSSpp sh
257(g)
40971
None
513(h)
Any
None
1537(i)
40968
None
WARNING
OFF
1793
Voice & Ctrl. Local 
Loop Test (#13)
MIN/WRN
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
ON
test port UUCSSpp l r 3
2049
NPE Crosstalk Test 
(#9)
MIN/WRN
2
ON
test port UUCSSpp l r 3
2305(j)
40967
None
3840(k)
40965
None
3840(l)
41029
None