Philips 320 Manuale Utente

Pagina di 24
is configured as a non-inverting output the output is zero 
and stays zero and awaits control by the software. 
If the output is configured as an inverting output than 
during the start-up sequence the output equals the value of 
the power supply. This situation stays that way until the 
software has taken over the control. In case a flash unit is 
switched to the on position with a positive input, the flash 
unit will flash or lit continuously. 
2.3.2.1 
Using the Trigger Input 
The trigger input is optically isolated that is different from 
the digital I/O as described in 2.3.3. 
The following diagram shows an example of how to use 
the optical Isolated input. 
24V
Inca
p
n
2K7
 
Figure 2-4 Optical isolated trigger input 
When the diode is conducting and thus emitting light, the 
software will interpret this as a binary ‘1’. 
The input is TTL level compatible. 
•  input current 6.3 mA < Ion < 10 mA 
•  Pmax 20 mW 
2.3.2.2 
Using the Flash and Watchdog 
Outputs 
The flash and watchdog outputs are optically isolated that 
are different from the digital I/O as described in 2.3.3. 
The following diagram shows an example of how to use 
the optical output. 
24V
2K7
Inca
p
n
 
Figure 2-5: Optical isolated flash and watchdog outputs 
When the flash output is defined as active high and the 
software sets the flash as active, then the state of the 
output is Ioff, and the transistor will not be conducting. 
When the flash output is defined as active low, and the 
software sets the flash as active, then the state of the 
output is Ion, and the transistor will be conducting. 
The watchdog will behave the same as the flash output in 
the active high definition. More information about the 
watchdog can be found in 2.3.4.3. 
 
2005-12-12
 
 
Page 7