DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install Management Terminal and Activate System 
Page 3-27
Administer Fiber Links (Release 6r Only) 
3
6. The Fiber Link Administration form appears. On Page 1, enter the 
Board 
Location: 
for ENDPOINT-1 and ENDPOINT-2. This is the cabinet, 
carrier, and slot that identifies the physical location of an SNI or EI circuit 
pack that is the first endpoint of the fiber link. Repeat for the remaining 
endpoints.
7. The 
Board Type
 field is display only and shows the type of circuit pack in 
Endpoint-1.
8. In the 
DS1CONV Board Location
: field, enter the cabinet, carrier, and 
slot that identifies the physical location of DS1 Converter circuit pack in 
the first endpoint of the duplicate fiber link. Endpoint-1’s duplicate along 
with Endpoint-2’s duplicate make up the duplicate fiber link called the 
B-PNC link.
9. The 
DS1CONV Board Type
: field is display only and shows the type of 
DS1 Converter circuit pack in Endpoint-1. The circuit pack type in 
Endpoint-1 (A-PNC) and Endpoint-1 (B-PNC) must be the same.
10. In the 
Is one endpoint remoted via a DS1 Converter 
Complex?
 field, enter y to specify that a DS1 Converter complex is used 
to remote 1 endpoint. If a is entered, administer the A-PNC DS1 
Converter Board Location on Page 1. The A-PNC DS1 Converter Board 
Type displays. Administer the A-PNC DS1 Converter (DS1CONV) 
Attributes on Page 2 of this form.
11. On Page 2 of the form, enter the DS1 Converter Facilities information. In 
the 
Facility Installed?
 field, enter y for all installed facilities (A, B, 
C, and D).
12. In the 
Bit Rate
:
 field, enter 1.544 for T1 operation or 2.048 for E1 
operation. 
NOTE:
One bit rate applies for all facilities within the same DS1 Converter 
complex. The 
Bit Rate:
 field displays only under Facility A.
13. Enter the idle code in the 
Idle Code MSB (1) . . . . LSB (8):
 
field. The default value is 11101000. It is recommended that the default 
value be used unless it becomes absolutely necessary to change it. The 
“MSB” means Most Significant Bit, the “LSB” means Least Significant Bit. 
14. In the 
Line Coding: 
field, enter the line coding information. This 
information should match the line coding of the facility. For T1, example 
line coding is b8zs. For E1, example line coding is hdb3. Scroll to Page 3 
and modify the fields as needed for the B-PNC.
NOTE:
If this data is not correct, wideband errors (such as multimedia call 
handling) may occur. 
15. For T1 sites, refer to 
. For E1 sites, refer to