Installation and Test for Multi-Carrier Cabinets  
555-230-112  
Issue 5
May 1998
Install and Wire Telephones and Other Equipment 
Page 5-38
Emergency Transfer Units and Associated Telephones 
5
NOTE:
Install the 808A in a location that can be accessed only by authorized 
personnel. In addition, the location must meet standard environmental 
considerations such as temperature, humidity, and so forth.
6. Install the panel on any mounting frame in either a vertical or horizontal 
position. The housing has ears for screw-mounting and cutouts for 
snap-mounting the unit in an 89-type mounting bracket. Verify dial tone is 
present at each trunk circuit.
7. Locate the circuit start selection switches. See 
These are the 
first 10 two-position switches on the left side of the panel. They are used to 
set each of the 5 incoming trunk lines to either loop start or ground start. 
Two switches are used for each circuit; switches 1 and 2 are used for 
circuit 1, switches 3 and 4 are used for circuit 2, and so forth. See 
Table 
5-13
. For loop start, set the switches to the left. For ground start, set the 
switches to the right.
.
8. Connect a 25-pair cable between the male RJ21 25-pair connector on the 
Emergency Transfer Panel and the yellow field of the MDF. Se
 shows the pin assignments.
9. Make cross-connections for each emergency trunk/emergency station 
pair. See 
Table 5-13.
Trunk/Test Switches
Switch 
Number
Circuit 
Number
1
1
2
1
3
2
4
2
5
3
6
3
7
4
8
4
9
5
10
5
11
Not Used
12
Test Switch