Lucent Technologies Release 6 Manuale Utente
DEFINITY Enterprise Communications Server Release 6
Installation and Test for Multi-Carrier Cabinets
Installation and Test for Multi-Carrier Cabinets
555-230-112
Issue 5
May 1998
Install and Wire Telephones and Other Equipment
Page 5-135
CAMA/E911 Installation
5
Screen 5-1.
CAMA Trunk Group form (page 1)
2. On Trunk Group screen (page 1), in the
Group Type:
field, enter cama.
3. In the
Group Name:
field, enter the desired name.
4. In the
TAC:
field, enter the desired trunk access code.
5. In the
Outgoing Display:
field, enter y.
6. In the
CESID I Digits Sent:
field, enter the number directed by the
Central Office (CO) or the Public Safety Answering Point (PSAP).
7. Scroll to page 3 of the form.
Screen 5-2.
Administrable Timers form (page 3)
Page 1 of 11
TRUNK GROUP
Group Number: 1 Group Type: cama CDR Reports: y
Group Name: cama Trunk Group - E911 COR: 1 TN: 1 TAC: 701
Direction: outgoing Outgoing Display? y CESID I Digits Sent: 0
Busy Threshold: 99
Group Name: cama Trunk Group - E911 COR: 1 TN: 1 TAC: 701
Direction: outgoing Outgoing Display? y CESID I Digits Sent: 0
Busy Threshold: 99
TRUNK PARAMETERS
Trunk Type: wink-start
Outgoing Dial Type: r1mf
Trunk Termination: rc
Trunk Type: wink-start
Outgoing Dial Type: r1mf
Trunk Termination: rc
Page 3 of 11
TRUNK GROUP
ADMINISTRABLE TIMERS
Outgoing Disconnect (msec): 400
Cama Outgoing Dial Guard (msec): 75
Outgoing Glare Guard (msec): 1000
Cama Outgoing Dial Guard (msec): 75
Outgoing Glare Guard (msec): 1000
Cama Wink Start Time (msec): 5000
Outgoing End of Dial (sec): 1 Outgoing Seizure Response (sec): 4
Disconnect Signal Error (sec): 30
Outgoing End of Dial (sec): 1 Outgoing Seizure Response (sec): 4
Disconnect Signal Error (sec): 30