May 1998
Install Management Terminal and Activate System
Page 3-18
Set System Maintenance Parameters
3
Set System Maintenance Parameters
If the system does not contain a TN778 Packet Control circuit pack, skip this
section and proceed to
section and proceed to
1. Verify the terminal screen displays:
Command:
2. Type change system-parameters maintenance
and press
Enter
. Verify
the screen displayed is similar to
Screen 3-5
. The screen shows default
values and the cursor is positioned on
Product Identification:
line.
Screen 3-5.
Typical System-Parameters Maintenance Screen
!
CAUTION:
To prevent unnecessary trouble tickets, do not enable the system
alarms (Alarm Origination feature) until all installation and
administration procedures are completed.
alarms (Alarm Origination feature) until all installation and
administration procedures are completed.
3. Move the cursor by pressing
Tab
to move down the screen from field to
field and enter
y
in the
Packet Bus Activated?
field to indicate a
TN778 circuit pack is installed. This is the only field needing change on
this screen to turn the red LEDs off.
this screen to turn the red LEDs off.
4. Press
Enter
when the information is correct.