VIVOTEK IP7139 Manuale Utente

Pagina di 109
- 89 - 
www.vivotek.com 
Drive the digital output 
Note: This request requires the privilege of viewer. 
Method: GET/POST 
Syntax: 
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>] 
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0, 1. “0” means inactive or normal state while “1” means active or 
triggered state. 
PARAMETER 
VALUE 
DESCRIPTION 
0 – inactive, normal state 
do<num>
0, 1 
1 – active, triggered state 
return
<return page> 
Redirect to the page <return page> after the
parameter is assigned. The <return page> can be
a full URL path or relative path according the the
current path. If you omit this parameter, it will
redirect to an empty page. 
Example: Drive the digital output 1 to triggered state and redirect to an empty page 
http://myserver/cgi-bin/dido/setdo.cgi?do1=
1
Query status of the digital input 
Note: This request requires the privilege of viewer. 
Method: GET/POST 
Syntax: 
98 - User's Manual
VIVOTEK - A Leading Provider of Multimedia Communication Solutions