dihigh 
0/1 
Enable/Disable trigger when input is high 
dilow 
0/1 
Enable/Disable trigger when input is low 
dirise 
0/1 
Enable/Disable trigger when input is rising 
difall 
0/1 
Enable/Disable trigger when input is falling 
motion1 
0/1 
Enable/Disable trigger when motion int window
#1 is detected 
motion2 
0/1 
Enable/Disable trigger when motion int window
#2 is detected 
motion3 
0/1 
Enable/Disable trigger when motion int window
#3 is detected 
ioalarm 
0/1 
Enable/Disable DO trigger when DI condition
matched 
mdalarm 
0/1 
Enable/Disable DO trigger when motion
detection condition matched 
ioupload 
0/1 
Enable/Disable upload snapshot when DI
condition matched 
mdupload 
0/1 
Enable/Disable upload snapshot when motion
detection condition matched 
seqop 
0/1 
Enable/Disable sequential operation 
sinter 
1 ~ 99999 
Interval of sequential snapshot in second 
mail 
Send snapshot by e-mail 
smethod 
ftp 
Send snapshot by ftp 
suffix 
0/1 
Enable/Disable FTP put snapshots with date and
time suffix 
resetdo 
0/1 
Reset/No reset DO when click save button 
   
Example: Enable sequential send snapshot by every 1 second with email. 
http://myserver/setup/app.vspx?method=set&exclude=1&eventop=0&seqop=1&
smethod=mail&sinter=1