Barco R59116700-01 Manuale Utente

Pagina di 125
94
Addendum
If a connection is possible with the Display Control application either remotely or locally, you
can use the Server Application Manager dialog to find out if the server application has been
installed, is running and which port and port name it is using and if an error occurred. In the
Display Control application, go to the Configure menu and select Server Applications. 
If a connection is not possible with the Display Control application, you will need to look at
the application event viewer on the Display Control server. 
The endpoint is a duplicate 
This error message suggests that an attempt to open a communication port failed because
it is already in use.
If the Display Control server has not been activated or the networking has been disabled in
the Display Control Administrator dialog or Display Control has not been activated, the
problem is with the port name.
If networking is enabled, the problem could be with either the port number or the port
name.
You can find out the port number and the port name that the server application is using
through the Server Application Manager dialog or the application event viewer.
You can find out which port numbers are in use on a machine with the netstat command.
There is no way to find out which port names are in use. 
Use the Server Application Manager to change  the  port  number  and/or  port  name  and
restart the server application.
The remote procedure call failed and did not execute 
This is displayed when trying to contact a server application that has been stopped after it
had been connected to successfully. Go to the Server Application Manager dialog and start
the server application again.
Changing Screen Resolution
Prior to making any changes to the resolution, it is recommended that the ECU server be
stopped beforehand. This can be done using the Server Application Manager dialog. 
The servers retain resources on the graphics card which my not be available if the resolution
is changed.