Zenoah BCZ2500S Manuale Utente

Pagina di 42
12. Troubleshooting guide
Case 1. Starting failure 
CHECK
PROBABLE CAUSES
ACTION
fuel tank
incorrect fuel
drain it and with correct fuel
fuel filter
fuel filter is clogged
clean
carburetor adjustment screw
out of normal range
adjust to normal range
sparking (no spark)
spark plug is fouled/wet
clean/dry
plug gap is incorrect
correct (GAP: 0.6~0.7mm)
spark plug
disconnected
retighten
Case 2. Engine starts but does not keep running/Hard re-starting.
CHECK
PROBABLE CAUSES
ACTION
fuel tank
incorrect fuel or staled fuel
drain it and with correct fuel
carburetor adjustment screw
out of normal range
adjust to normal range
muffler,cylinder (exhaust port)
carbon is built-up
wipe away
air cleaner
clogged with dust
wash
cylinder fin, fan cover
clogged with dust
clean
When your unit seems to need further service, please consult with our RedMax service shop in your area. 
31