Chauvet 64-36VWC Manuale Utente

Pagina di 15
LED Par 64-36VW B&C User Manual 
11 
Rev. 4 
Custom Static Color Mixing 
This fixture has the ability to accept custom static color settings. These are accessed via the control panel. 
Please see the instructions below for further explanation. 
1. 
Press <MENU> until 
U--
 appears on the LED screen. 
2. 
Press <ENTER>
3. 
Using <UP> and <DOWN>, select the desired color value (
000
~
100
). By selecting 
000
, the color 
will remain off.  
4. 
Press <ENTER> to continue to the next color (
r, C
). 
5. 
Using <UP> and <DOWN>, select the desired color value (
000
~
100
). By selecting 
000
, the color 
will remain off. 
6. 
Continue until the desired mix is obtained. 
7. 
Press <ENTER> to save the final color setting. This will move the selection to the following color. 
However, this is necessary to save the modification. 
 
The colors are represented by the following in the menu map: 
r--- 
= Warm White (
000
~
100
C--- 
= Cool White (
000
~
100
 
DMX Channel Values 
4-CH 
 
C
HANNEL
 
V
ALUE
 
F
UNCTION
 
 
000 
ó 255 
Master Dimmer 
Dimmer: 0%~100% 
 
000 
ó 255 
Warm White (2900K) 
Dimmer: 0%~100% 
 
000 
ó 255 
Cool White (6300K) 
Dimmer: 0%~100% 
 
000 
ó 015 
016 
ó 255 
Strobe 
No function 
Strobe: 0%~100% 
2-CH 
 
C
HANNEL
 
V
ALUE
 
F
UNCTION
 
 
000 
ó 255 
Warm White (2900K) 
Dimmer: 0%~100% 
 
000 
ó 255 
Cool White (6300K) 
Dimmer: 0%~100% 
Setting the Starting Address 
This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address 
from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start 
on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start 
addresses so that the channels used do not overlap, and note the start address selected for future reference.