AC Power 
Each Legend™ 412Z has an auto-ranging power supply that works with an input voltage range 
of 100 to 240 VAC, 50/60 Hz. To determine the power requirements for each Legend™ 412Z, 
refer to the label affixed to the product. You can also refer to the 
 chart 
in this manual. 
The listed current rating indicates the maximum current draw during normal operation. For more 
information, you may download Sizing Circuit Breakers from the CHAUVET® website: 
. 
 
Always connect this product to a protected circuit with an appropriate electrical ground 
to avoid the risk of electrocution or fire. 
 
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even if the 
rheostat or dimmer channel serves only as a 0 to 100% switch. 
AC Plug 
The Legend™ 412Z comes with a Neutrik® powerCON A connector on one end and an Edison 
plug on the other end (US market). If the power cord adapter that came with your product has 
no plug or you need to change the Edison plug, use the table below to wire the new plug.. 
 
Connection 
Wire (U.S.) 
Wire (Europe) 
Screw Color 
AC Live 
Black 
Brown 
Yellow or Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
 
Fuse 
Replacement 
1.  Disconnect this product from the power outlet. 
2.  Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the housing. 
3.  Remove the blown fuse and replace with another fuse of the same type and rating  
(T 6.3 A, 250 V). 
4.  Screw the fuse holder cap back in place and reconnect power. 
 
Make sure to disconnect the product’s power cord before replacing a blown fuse. Always 
replace the blown fuse with another of the same type and rating. 
Power Linking 
The Legend™ 412Z supports power linking. You can power link up to 9 products at 120 V; up to 
15 at 208 V; or up to 17 at 230 V. 
This product comes with a power input cord. Power linking cables are available from 
CHAUVET® for purchase. 
DMX Linking 
You can link the Legend™ 412Z to a DMX controller using a standard DMX serial connection. If 
using other DMX compatible products with the Legend™ 412Z, you can control each 
individually with a single DMX controller. 
DMX Modes 
The Legend™ 412Z uses the standard DMX data connection for the 15-, 27-, 31-, and  
34-channel DMX modes. 
·  Refer to the 
 chapter for a brief description of these modes.  
·  Refer to the 
 chapter to learn how to configure the Legend™ 412Z to work in 
these modes.  
·  The 
DMX Values
 section provides you with detailed information regarding the DMX modes.