Wybron N/A Manuale Utente

Pagina di 22
16
75-79%
15 sec
80-84%
16 sec
85-89%
17 sec
90-94%
18 sec
95-100%
19 sec
Head-Feet Restrictions
HEAD-FEET is defined as "the sum of cable lengths from each color changer to a single 
power supply output".  
The HEAD-FEET parameter is a method of accounting for the voltage drop in the 
power/signal cable caused by the current drawn by each color changer.  
To help understand this issue, think of it as water pressure (voltage) in a hose (cable) 
where you have multiple water sprinkler heads (color changers). If the hose (cable) is 
too long or you have too many sprinkler heads (color changers), the water pressure 
(voltage) will be too low.
The maximum HEAD-FEET for each of the CXI color changers is as follows:
Model 4560  4-inch CXI      
750 head-feet max.
Model 7200  7.5-inch CXI   
750 head-feet max. 
Model 12210 12-inch CXI    
500 head-feet max.
Model 7420 MultiPAR CXI 
1500 head-feet max.
Model 16050 Large Format CXI
750 head-feet max.
"Head-Feet" Example:
There are three CXI Color Changers connected to a power supply. The Coloram II 
Cable between the power supply and the first CXI is 100 feet long. The cables between 
each of the CXI's is 20 feet long.
The amount of cable from the power supply to:
1st CXI   
100 ft
2nd CXI  
120 ft
3rd CXI   
140 ft
total:
360 "head-feet"
Fan Speed Control
Set the fan speed control with the push-button / display via the FAN selection.  
1.
RMOT (Remote control) -- the commands from the power supply