Chauvet Quad 6 Manuale Utente

Pagina di 20
COLORdash™ Batten Quad 6 QRG 
EN 
About this 
Guide 
The  COLORdash™ Batten Quad 6  Quick Reference Guide (QRG) has 
basic product information such as connection, mounting, menu options, and 
DMX values. Download the User Manual from 
www.chauvetlighting.com
 
for more details. 
Disclaimer 
The  information and specifications contained in this QRG are subject to 
change without notice. 
Safety Notes
 
• 
DO NOT open this product. It contains no user-serviceable parts. 
• 
DO NOT look at the light source when the product is on. 
• 
CAUTION: This product’s housing may be hot when lights are 
operating.  
• 
Mount this product in a location with adequate ventilation, at least 20 
in (50 cm) from adjacent surfaces.  
• 
DO NOT leave any flammable material within 50 cm of this product 
while operating or connected to power. 
• 
USE a safety cable when mounting this product overhead. 
• 
DO NOT operate this product outdoors or in any location where dust, 
excessive heat, water, or humidity may affect it. 
• 
DO NOT operate this product if the housing, lenses, or cables appear 
damaged.  
• 
DO NOT connect this product to a dimmer or rheostat. 
• 
ONLY connect this product to a grounded and protected circuit. 
• 
ONLY use the hanging/mounting bracket to carry this product. 
• 
In the event of a serious operating problem, stop using immediately.  
• 
The maximum ambient temperature is 104° F (40° C). Do not operate 
this product at higher temperatures.  
Contact
 
Outside the U.S., United Kingdom, or Ireland, contact your distributor to 
request support or return a product. Visit 
www.chauvetlighting.com
  for 
contact information.
 
What Is 
Included 
• 
COLORdash™ Batten Quad 6 
• 
Power Input Cord 
• 
Safety Cable 
• 
Warranty Card 
• 
Quick Reference Guide 
AC Power 
This product has an auto-ranging power supply that can work with an input 
voltage range of 100~240 VAC, 50/60 Hz. 
Power Linking 
You can link up to 17 COLORdash™ Batten Quad 6 products at 120 VAC 
or 33 at 230 VAC. Never exceed this number. Power linking cords can be 
purchased separately. 
AC Plug 
Connection 
Wire (U.S.) 
Wire (Europe) 
Screw Color 
AC Live 
Black 
Brown 
Yellow/Brass 
AC Neutral 
White 
Blue 
Silver 
AC Ground 
Green/Yellow 
Green/Yellow 
Green 
 
Fuse 
Replacement  
1.  Disconnect this product from the power outlet. 
2.  Wedge the tip of a flat-head screwdriver into the slot of the fuse holder. 
3.  Pry the safety cap out of the housing pulling out the installed fuse. 
4.  Remove the blown fuse from the safety cap and replace with a fuse of 
the exact same type and rating.  
5.  Insert the fuse holder back in place and reconnect power.