Page 7 of 19 
3.
 
S
ETUP
 
 
 
AC Power 
The SlimBANK™ TRI-18 has an auto-ranging power supply and it can work with an 
input voltage range of 100 to 240 VAC, 50/60 Hz. 
To determine the product’s power requirements (circuit breaker, power outlet, and 
wiring), use the current value listed on the label affixed to the product’s back panel, or 
refer to the product’s specifications chart. The listed current rating indicates the 
product’s average current draw under normal conditions. 
 
 
 
Always connect the product to a protected circuit (circuit breaker or fuse). Make 
sure the product has an appropriate electrical ground to avoid the risk of 
electrocution or fire. 
 
 
 
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even 
if the rheostat or dimmer channel serves only as a 0 to 100% switch. 
 
 
Fuse 
Replacement
 
 
 
Disconnect the product from power before replacing the fuse. 
 
1.  Disconnect the product from power. 
2.  Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.  
3.  Pry the fuse holder out of the housing. 
4.  Remove the blown fuse from the holder. 
5.  Replace with a fuse of the exact same type and rating. 
6.  Insert the fuse holder back in place and reconnect power. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
A spare fuse is not included; however, the safety cap has room for a spare.  
 
 
 
Always replace a blown fuse with another of the same type and rating. 
 
 
 
 
 
Installed fuse  
(held by plastic clip) 
Spare fuse holder  
(inside safety cap) 
Safety cap