Multiquip BGMP Manuale Utente
GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #0 (07/23/09) — PAGE 31
MAINTENANCE
Periodic Check and Maintenance
Table 7.
FIGURE
PART
CHECK ITEM
SOLUTION
Lamp
L1
Lamp (Base)
Lamp base loose?
Screw in securely.
•
L2
Connector
Cable disconnected or loose?
Connect securely.
•
L3
Lamp Holder
Lamp holder loose?
Replace.
#
L4
Pipe Frame
Pipe Frame skewed
Replace.
&
L5
Lamp
Defective lamp?
Replace.
•
Balloon
B1
Balloon (Envelope)
Defective or dirty?
Replace.
•
B2
Zipper
Broken?
Replace.
•
B3
Fan Motor (Blower)
Not working properly?
Repair or replace.
$
B4
Buckle
Broken?
Replace.
$
B5
T-handle bolt (balloon)
Broken?
Replace.
•
Pentapod
P1
Pentapod
Damaged or Not Working Properly? Replace.
#
P2
Mast
Damaged or Not Working Properly? Replace.
#
P3
Latch
Damaged?
Replace.
•
P4
Stopper
Damaged?
Replace.
•
Electric
E1
Power cable
Defective or worn cable?
Replace.
•
E2
Plug
Damaged?
Replace.
#
Offset Pole
S1
Clamp
Damaged?
Replace.
•
S2
Straight Pole
Damaged or Skewed?
Replace.
$
S3
Offset Pole
Damaged or Skewed?
Replace.
$
S4
Knob
Loose?
Tighten Securely.
•
• — Check daily
# — Every 20 hours
$ — Every 100 hours
& — Every 500 hours