MAINTENANCE
Periodic Check and Maintenance
Table 7. 
FIGURE
PART
CHECK ITEM
SOLUTION
Lamp
L1
Lamp (Base)
Lamp base loose?
Screw in securely.
L2
Connector
Cable disconnected or loose?
Connect securely.
L3
Lamp Holder
Lamp holder loose?
Replace.
#
L4
Pipe Frame 
Pipe Frame skewed
Replace.
&
L5
Lamp
Defective lamp?
Replace.
Balloon
B1
Balloon (Envelope)
Defective or dirty?
Replace.
B2
Zipper
Broken?
Replace.
B3
Fan Motor (Blower)
Not working properly?
Repair or replace.
$
B4
Buckle
Broken?
Replace.
$
B5
T-handle bolt (balloon)
Broken?
Replace.
Pentapod
P1
Pentapod
Damaged or Not Working Properly? Replace.
#
P2
Mast
Damaged or Not Working Properly? Replace.
#
P3
Latch
Damaged?
Replace.
P4
Stopper
Damaged?
Replace.
Electric
E1
Power cable
Defective or worn cable?
Replace.
E2
Plug
Damaged?
Replace.
#
Offset Pole
S1
Clamp
Damaged?
Replace.
S2
Straight Pole
Damaged or Skewed?
Replace.
$
S3
Offset Pole
Damaged or Skewed?
Replace.
$
S4
Knob
Loose?
Tighten Securely.
• — Check daily
# — Every 20 hours
$ — Every 100 hours