TROUBLE SHOOTING GUIDE — 
WARNING!
 
Let unit cool before servicing! 
 
 
Symptom 
Probable Cause 
Corrective Action 
No fog — Burner 
works. 
1) 
Spray tip and/or end of 
heater coil obstructed or 
clogged. 
1) 
LET UNIT COOL! Remove Spray tip 
and check for blockage. Clean spray 
tip to remove blockage. With spray tip 
removed, use a pipe cleaner to clear 
out carbon build-up that may be 
inside the burner coil. Replace spray 
tip and tighten securely. 
 
2) Pump plugged. 
2) 
Remove Insecticide Vessel. With 
fogger on its side, carefully remove 
Plastic Pump Assembly Cover (be 
aware of spring & bearing inside 
cover) from fogger. Insert a small wire 
into hole in bottom of Pump Assembly 
(clearing any blockage). Carefully 
replace Plastic Pump Assembly cover 
with spring & bearing inside. 
 
3) Piston cup worn. 
3) 
See parts & service on next page. 
 
4) Improper fogging material. 
4) 
Use only insecticide for thermal 
fogging. 
No fog — burner not 
working. 
1) 
Propane cylinder empty. 
1) 
Replace propane cylinder. 
 
2) 
Propane tank attached 
improperly. 
2) 
Check to see if propane cylinder is 
properly attached. 
 
3) 
Burner assembly fails to 
light or will not stay lit. 
3) 
Check igniter. Test lighting unit using 
a match. 
Dripping. 
1) 
Spray tip loose 
1) 
Tighten spray tip securely   
 
2) 
Excessive insecticide 
output. 
2) 
Decrease your pumping rate. 
 
3) 
Not at operating 
temperature. 
3) 
Wait 60 seconds before pumping. 
Poor fog quality. 
1) 
Improper fogging material. 
1) 
Use only Bonide insecticide. 
 
2) 
If fog is thin or yellowish 
pumping rate is too low. 
2) 
Increase your pumping rate. 
 
3) 
If fog is wet and dripping. 
3) 
Decrease your pumping rate.