750733-100 Rev. F
INSTALLATION INSTRUCTIONS
SCALA™ 5-1/2 
WHIRLPOOL/BATHING POOL
2645 SERIES 
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard nc un ess otherwise noted
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
T H A N K     Y O U . . .
for selecting an American Standard bath. Your new 
bath is shipped to you after careful inspection. The 
whirlpool version is completely assembled with pump, 
motor, and system piping. All you need to finish the 
installation are your selected fittings and electrical 
connections for a whirlpool.
To insure maximum performance and pleasure from 
this product, please follow the instructions and 
cautions. 
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any 
shipping damage. If such damage is found, report it to 
your vendor immediately.
After inspection and during installation, protect the bath 
from construction damage. After installation, and before 
enclosing with wallboard, tile, etc., water test the unit 
and check for leaks.
If a whirlpool, do not make modifications to the whirlpool 
system or remove pump from factory mounting. This 
could adversely affect the safety and performance of the 
whirlpool and void the warranty. Do not handle or move 
the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided 
with the bath and must be ordered separately. Framing 
and enclosing materials are provided by others. Check 
for availability of optional American Standard wall tiling 
bead (required for recess installations).
Protect all finished surfaces of the whirlpool during 
construction and installation using a drop cloth.  
WARNING! Do not lift whirlpool by the piping har-
ness at any time.
List of Optional Components (not included):
•  Apron Kit*
* see your American Standard Distributor
List of Required Components (not included):
•  Drain 1583.470*       •  Bath Filler* 
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun
Supplies
•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  15 amp 
      GFCI Outlet
•  Cement, Plaster,
      Grout
C/L OF 
   DRAIN
1676mm
(66)
6mm
(1/4)
TYP.
25mm (1)
TYP.
302mm
(11-7/8)
PROVIDE ACCESS
TO PUMP FOR
SERVICING ON ALL
INSTALLATIONS
914mm
(36)
51mm
(2)
HAND SHOWER 
LOCATION
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2" x 13")
OUTLINE OF CUTOUT
1626mm X 864mm 
(64 X 34)   
419mm
(18)
44mm
(1-3/4)
210mm
(8-1/4)
ON/OFF
SWITCH
PUMP
229mm X 305mm
(9 X 12) CUTOUT
FOR DRAIN
1-1/2 O.D. TAILPIECE
 
1-1/2 N.P.T.M. THREADS
INTEGRAL
FEET SUPPORT
502mm
(19-3/4)
464mm
(18-1/4)
457mm
(3-5/8)
44mm
(1-3/4)
38mm
(1-1/2)
102mm
(4)
LEVELING STRINGER
(NOT FOR SUPPORT)
66 x 36 x 19-3/4 In. (1676 x 914 x 502mm)
 95 Lbs. (43 Kg.)
595 Lbs. (268 Kg.)
60 Gal. (227 L)
 55 Gal. (208 L)
46 x 24 In. (1168 x 610mm)
62 X 31-1/2 In. (1575 x 800mm)
13-1/4 In. (337mm)
36 Lbs./Sq.Ft. (175 Kgs/Sq.m)
25.6
45.1
GENERAL SPECIFICATIONS FOR 2645 WHIRLPOOL
1.1 HP, 9.9 AMPS,120V.
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT