11.0  automatic Filtration Cycles
Your new spa includes a 8-hour circulation pump which filters the water 
continuously. The circulation pump draws water through the skimmer bag 
and one of two filter cartridges to effectively remove small debris in your spa. 
note: The 8-hour circulation pump system also supplies heated water to 
the spa when the heater turns on. The pump is not programmable.
The control system activates a programmable “Standard” or “Economy” 
filtration/heating cycle to remove larger debris missed by the 8-hour 
circulation pump filtration system. These cycles utilize pump #1 low 
speed and the second filter cartridge to quickly “skim” the water of large 
debris and minimize their “bath-tub ring” effect. Apart from their skimming 
benefit, each mode also effects the operation of your spa’s heater. Refer 
to Sections 11.1 and 11.2 below for additional information.
11.1 
standard Filtration/heating Modes (F0-F3)
Standard filtration/heating modes are typically selected by customers in 
cold climates where heat up times are extended due to lower ambient 
temperatures. In these modes, the water temperature is regulated by the 
set temperature, 8-hour circulation pump, jets pump 1, and heater which 
turns on as needed. After the programmed set temperature is reached, 
the heater turns off and the circulation pump continues to operate 
24-hours to filter and clean your spa unless in summer logic; see Section 
economy Filtration/heating Modes (F4-F6)
Economy filtration/heating modes are typically selected by customers in 
warm climates where heat up times are minimized due to higher ambient 
temperatures. In these modes, the water temperature is regulated by the 
set temperature, 8-hour circulation pump, jets pump 1, and heater only 
while a programmed filter cycle is running (unless in summer logic; see 
Section 14.1, page 42).
11.3 
lock modes (l1-l2)
These modes are designed for use during spa service or to prevent 
unauthorized use.
11.4 
selecting the Filtration/heating Mode
Press and hold both control panel 
warmer (   ) and Cooler (   ) 
buttons at the same time, then release. Then press either 
warmer  
(   ) or 
Cooler (   ) button to select filtration/heating mode F0-F6 or 
lock modes L1-L2. During the filtration/heating cycle the jets pump 1 low 
speed and circulation pump will activate.