MAINTENANCE
STORING THE PRESSURE wASHER
See Figure 27.
Store the pressure washer with the gas tank empty by either 
draining the tank or running the pressure washer until the 
gas runs ou
t. Allow 30 minutes of “cool down” time be
fore 
storing the machine. Store in a dry, covered area where the 
weather can’t damage it.
It is important to store this product in a frost-free area. Always 
empty water from all hoses, the pump, and the detergent 
container before storing. 
NOTE: Use of a fuel stabilizer and pump saver will give you 
better performance and increase the life of the machine.
Trigger and auxiliary handles:
Remove  the  auxiliary  handle  from  the  trigger  handle  and 
store the auxiliary handle in the storage hole on the side of 
the trigger handle.
Remove the spray wand from the trigger handle by turning 
the  connector  counterclockwise. 
Store  the  unassembled 
spray wand in the spray wand sto
rage area.
Discharge Fuel:
Drain the fuel tank completely. Stored gas can go stale in 
30 days.
Engine Oil:
Drain the oil and replace with fresh, clean oil.
Spark Plug:
Disconnect spark plug wire and remove the spark plug. 
Pour about a teaspoon of clean, air-cooled, four-cycle 
oil  through  the  spark  plug  hole  into  the  combustion  
chamber.
Leaving the spark plug out, pull the starter cord two or 
three times to coat the inside of the cylinder wall.
Inspect the spark plug and clean or replace, as neces-
sary. 
Reinstall the spark plug, but leave the spark plug wire 
disconnected.
Air Filter:
Clean the air filter.
Hoses and Pump:
Flush the injection hose with clean water for 1- minutes. 
Remove all hoses. Empty the pump by pulling on the recoil 
starter about 6 times. This should remove most of the liquid 
from the pump.
PREPARING FOR USE AFTER STORAGE
Pull the recoil starter grip three or four times to clean oil 
from the combustion chamber.
Remove spark plug from the cylinder. Wipe oil from the 
spark plug and return it to the cylinder.
Reconnect the spark plug wire.
Refuel the machine as described earlier in the operator’s 
manual.
to store the mAchiNe
Fig. 7
PUMP MAINTENANCE
We recommend having the pump lubricant changed every 
00 hours to ensure longer life of the machine. This service 
should be performed by an authorized service center.