GE 40350 Manuale Utente

Pagina di 120
8
After removing the carton, carefully inspect the generator for 
any damage that may have occurred during shipment.
If loss or damage is noted at time of delivery, have the 
person(s) making delivery note all damage on the freight bill 
and affix his signature under the consignor’s memo of loss or 
damage. If loss or damage is noted after delivery, separate 
the damaged materials and contact the carrier for claim 
procedures. Parts damaged in shipping are not warranted.
Delivery inspection
the home generator system is supplied with:
•  Oil (5W30 Synthetic)
•  Flexible steel fuel line
•  Installation and start-up manual
•  Operator’s manual
•  Spare access keys
•  Spare 15 Amp ATO-type fuse
•  Remote wireless monitor
•  Antenna
not included:
•  Carbon monoxide detector(s)
•  Smoke detector(s)
•  Starting battery
•  Connecting wire and conduit
•  Fuel supply valves/plumbing
•  Crane, lifting straps, chains or cables
•  Two 60” lengths of 3/4” nominal minimum scheduled
40 steel pipe (NOT conduit)
•  Torque screwdriver, 5 to 50 inch-pound range
•  Voltage/frequency meter
•  Two (2) AA batteries for remote wireless monitor
shipment contents
Avoid damage from dropping, bumping, collision, etc. Store 
and unpack carton with the proper side up, as noted on the 
shipping carton.
unpacking Precautions
cold Weather Kit
If operating the generator below 30°F (-1°C), it is hiGhLY
recoMMenDeD
 that a Model 6262 Cold Weather Kit
(includes oil warmer and battery warmer) be installed on the 
8kW units and that a Model 6030A Cold Weather Kit
(includes oil warmer and battery warmer) be installed on the 
10kW units.
These items are available at your local servicing dealer.
For cold weather areas (below 0°F (-18°C)) it is also 
recommended that a BCI, Size 26, wet lead-acid battery be 
used of 630 CCA minimum.
If you need more information on this matter, please call 
(888) 575-8226, between 8:00 AM and 5:00 PM CT.
30°F (-1°C)
NOT 
for 
REPRODUCTION