York P3DHX12F08001 Manuale Utente
11
TABLE A-1: BECKETT OIL BURNER SET-UP
BECKETT AF SERIES OIL BURNERS
FURNACE
MODEL
OUTPUT
BTU/Hr.
BURNER
MODEL
NOZZLE
(Delavan)
PUMP
PRESSURE
FLOW
RATE
HEAD
STATIC
PLATE
60,000
3
AF76BNHS
0.50 / 80°A
100 PSIG
0.50 GPH
F3
1
3-3/8
in.
78,000
2
AF76BNHS
0.65 / 80°A
100 PSIG
0.65 GPH
F3
1
3-3/8
in.
P3DHX12F08001
90,000
AF76BNHS
0.75 / 80°A
100 PSIG
0.75 GPH
F3
1
3-3/8
in.
91,000
AF76XN
0.75 / 80°A
100 PSIG
0.75 GPH
F3
2-3/4 in.
101,000
AF76XN
0.85 / 80°A
100 PSIG
0.85 GPH
F3
2-3/4 in.
117,000
2
AF76XN
1.00 / 60°A
100 PSIG
1.00 GPH
F3
2-3/4 in.
P2DHX16F12001
128,000
AF76YB
1.10 / 70°A
100 PSIG
1.10 GPH
F6
2-3/4 in.
130,000
AF65YB
1.10 / 70°A
100 PSIG
1.10 GPH
F6
2-3/4 in.
P2LBX16F14501
143,000
2
AF65YB
1.20 / 60°A
100 PSIG
1.20 GPH
F6
2-3/4 in.
168,000
AF81WF
1.50 / 70°B
100 PSIG
1.50 GPH
F16
2-3/4 in.
P4LBX20F19001
188,000
2
AF81WF
1.65 / 70°B
100 PSIG
1.65 GPH
F16
2-3/4 in.
1
Used with ceramic insulator.
2
Factory supplied nozzle.
3
Requires a low firing rate baffle.
In the United States, the R. W. Beckett “AF” Burner may be equipped with Beckett’s “Inlet Air Shut-Off”, Beckett Part No. AF/A 5861, to increase efficiency. It reduces the
amount of air passing through the oil burner, combustion chamber, breeching, etc. up the chimney between burner cycles.
NOTE: THE USE OF THIS CONTROL CAN OCCASIONALLY CAUSE POST COMBUSTION NOZZLE DRIP.
amount of air passing through the oil burner, combustion chamber, breeching, etc. up the chimney between burner cycles.
NOTE: THE USE OF THIS CONTROL CAN OCCASIONALLY CAUSE POST COMBUSTION NOZZLE DRIP.