York P3DHX12F08001 Manuale Utente

Pagina di 36
 
11 
 
 
TABLE A-1: BECKETT OIL BURNER SET-UP 
BECKETT AF SERIES OIL BURNERS 
FURNACE 
MODEL
 
OUTPUT 
BTU/Hr.
 
BURNER 
MODEL
 
NOZZLE 
(Delavan)
 
PUMP 
PRESSURE
 
FLOW 
RATE
 
HEAD 
STATIC 
PLATE
 
60,000 
3
 
AF76BNHS 
0.50 / 80°A 
100 PSIG 
0.50 GPH 
F3 
1
 3-3/8 
in. 
78,000 
2
 
AF76BNHS 
0.65 / 80°A 
100 PSIG 
0.65 GPH 
F3 
1
 3-3/8 
in. 
P3DHX12F08001 
90,000 
AF76BNHS 
0.75 / 80°A 
100 PSIG 
0.75 GPH 
F3 
1
 3-3/8 
in. 
91,000 
AF76XN 
0.75 / 80°A 
100 PSIG 
0.75 GPH 
F3 
2-3/4 in. 
101,000 
AF76XN 
0.85 / 80°A 
100 PSIG 
0.85 GPH 
F3 
2-3/4 in. 
117,000 
2
 
AF76XN 
1.00 / 60°A 
100 PSIG 
1.00 GPH 
F3 
2-3/4 in. 
P2DHX16F12001 
128,000 
AF76YB 
1.10 / 70°A 
100 PSIG 
1.10 GPH 
F6 
2-3/4 in. 
130,000 
AF65YB 
1.10 / 70°A 
100 PSIG 
1.10 GPH 
F6 
2-3/4 in. 
P2LBX16F14501 
143,000 
2
 
AF65YB 
1.20 / 60°A 
100 PSIG 
1.20 GPH 
F6 
2-3/4 in. 
168,000 
AF81WF 
1.50 / 70°B 
100 PSIG 
1.50 GPH 
F16 
2-3/4 in. 
P4LBX20F19001 
188,000 
2
 
AF81WF 
1.65 / 70°B 
100 PSIG 
1.65 GPH 
F16 
2-3/4 in. 
1
 Used with ceramic insulator.   
2
  Factory supplied nozzle. 
3
  Requires a low firing rate baffle. 
In the United States, the R. W. Beckett “AF” Burner may be equipped with Beckett’s “Inlet Air Shut-Off”, Beckett Part No. AF/A 5861, to increase efficiency. It reduces the 
amount of air passing through the oil burner, combustion chamber, breeching, etc. up the chimney between burner cycles. 
NOTE: THE USE OF THIS CONTROL CAN OCCASIONALLY CAUSE POST COMBUSTION NOZZLE DRIP.