Roland VR-700 Manuale Utente

Pagina di 84
 
57
 
Various Settings (Function mode)
 
With the Group already selected, press the [+] button or [–] button until 
 is shown in the display.
* Settings for parameters other than Local Control are saved in system memory. After editing these, press the [WRITE] button to save the 
* The shaded parameters are stored in system memory.
 
MIDI Input/Output Settings
 
Button
Parameter
Value
Factory setting
 
[PIANO]
Local Control
Internally connects (ON) or disconnects (OFF) the sound generator of 
the organ sounds and ensemble sounds with the keyboard and other 
controllers (p. 65).
* To prevent problems such as there being no sound, the Local Control 
setting is automatically turned on when you turn on the power.
* If you turn Local Control off, the keyboard unit connected to the MIDI 
PEDAL IN connector will be disconnected from the sound generator.
OFF, ON
ON
(at power-up)
[E.PIANO]
Device ID
Specifies the ID number used to identify units when using system 
exclusive messages to change the VR-700’s settings.
17–32
17
[STRINGS]
Sub Keyboard Function
Specifies the part that will be played by a keyboard connected to the 
MIDI IN connector (p. 66).
OFF, 
-U- (UPPER), 
-L- (LOWER)
OFF
[CHOIR/SCAT]
MIDI Thru Switch
Specifies whether messages received at the MIDI IN connector will be 
transmitted from the MIDI OUT connector (p. 66).
OFF, ON
ON
[BRASS]
USB MIDI Thru Switch
Specifies whether MIDI Thru will be used on the computer when the USB 
MIDI connector is connected to your computer (p. 67).
OFF, ON
OFF
[SYNTH LEAD]
Transmit Program Change Switch
Specifies whether the corresponding MIDI message will be transmitted 
when you switch Favorites.
OFF, ON
ON
[SYNTH PAD]
Receive Program Change Switch
Specifies whether incoming program change messages will switch 
Favorites.
OFF, ON
ON
[GUITAR]
Upper Organ MIDI Channel
1–16
1
[BASS]
Lower Organ MIDI Channel
1–16
3
[OTHERS]
Pedal Organ MIDI Channel
1–16
2
VR-700_e.book 57 ページ 2009年11月18日 水曜日 午前9時24分