System 5-B Digital Audio Mixing System Operation Manual
 
Quickstart to Common Task
28
3.2
Connect and Monitor a Microphone
Configure PatchNet
1. From the left side of PatchNet, select the Cabling tab.
2. Select MADI In Ports and select Hub 1-8 (any Hub can be selected). 
3. Select MADI Out Ports and click in the MADI Out column next to Mic 1. 
This tells the SH612 where the AM713 (which is connected to the ML530) is 
connected. 
4. Click Patch
Figure 3-3 Cabling
Assign a Channel to the Console
1. Select Channels from the Main Panel Viewer.
2. Select Auto then Channel 3.
3. Press the Chan Sel key on a Strip. 
4. Press the Inpt button on the strip, then turn the Inpt knob clockwise until the 
B input is selected.
5. Press the X button at the bottom of the knobset to display the B input page on 
the knobset.
Back to PatchNet
1. In PatchNet, select Console I/O, then select A and B Inputs.
2. Select the blue selection box for the B Input of Channel 3.
The patch point shows up in Selected - Destinations.
3. Select Device Outputs.