Installing a New G700 without an S8300
Configure the G700
Installation and Upgrades for G700 and S8300
179
December 2003
Assign the IP address to the P330 stack processor 
CAUTION:
The 
nvram init
 command initializes the switch parameters to the factory defaults. This 
command is normally used only for new installations. 
1
Initialize NVRAM: type 
nvram init
2
Change mode to configure: type 
configure
3
At the P330-1(super)# prompt, type 
configure
4
At the P330-1(configure)# prompt, type
set interface inband
 <
vlan> <ip_address> <netmask> 
to assign an IP address to the P330 stack 
processor.<vlan> is the vlan number, usually 1, to be established on the S8300 for the G700 
Media Gateways. The <ip_address> <netmask> is the assigned addresses for the P330 stack 
processor. 
5
Type reset and press 
Enter
 to reset the stack. 
6
Select 
Yes 
at the dialog box that asks if you want to continue. 
All LEDs will flash. As the unit powers up, self-tests will be run. When the G700 mpg or P330 
stack processor has reset, login again to continue. 
7
Login at the 
Welcome to P330
 menu.
The prompt P330-1(super)# appears.
8
Type 
configure
 to obtain the P330-1(configure)#
 
prompt. 
Establish the IP Routing for the Stack 
1
Type 
show interface inband
 to verify that the Avaya P330 stack server (Layer 2 Switching 
Processor) has the correct address.
2
Type 
set ip route 0.0.0.0
 
<default-gateway> 
to set the destination and gateway IP addresses. You 
will find these addresses in the planning documentation. 
<default-gateway> is the IP address of the customer’s network gateway.
3
Press 
Enter
 to save the destination and gateway IP addresses.
4
Type 
show ip route
.
The route net and route host tables appear. Verify that the information is correct.
Check the serial number of the G700 Media Gateway processor
After you have configured the P330 stack processor, you will assign an IP address to the G700 
Media Gateway Processor (MGP). Your first step is to check the serial number of the MGP.
1
At the P330-1(configure)#
 
prompt, type 
session mgp
.
2
At the MG-???-1(super)# prompt, type 
show system
 to list various attributes of the G700. 
The system displays a list of attributes, as shown in the following example: