Roland TD-9 Manuale Utente

Pagina di 80
 
64
 
Error Messages
 
If an error message appears in the TD-9’s screen, the TD-9 has failed to operate correctly for some reason, or an incorrect operation 
has been performed. Please take the appropriate action described here.
 
Message
Meaning
Action
 
MIDI-related error messages
 
MIDI Offline!
 
A MIDI cable was disconnected. (Or communi-
cation with the external MIDI device stopped 
for some reason.)
Make sure that MIDI cables have not been 
pulled out or broken.
 
MIDI Com Error!!
 
A problem has occurred with the internal sys-
tem.
Contact your dealer or a nearby Roland ser-
vice center.
 
Receive buffer full!
 
A large amount of MIDI messages were re-
ceived in a short time, and could not be pro-
cessed completely.
Confirm that the external MIDI device is prop-
erly connected. If the problem persists, reduce 
the amount of MIDI messages sent to the TD-9.
 
Transmit buffer full!
 
The TD-9 was attempting to transmit more data 
than could be correctly output from MIDI OUT.
Reduce the amount of data that is being trans-
mitted.
 
USB-related error messages
 
USB memory not Ready!
 
USB memory key is not connected.
Connect your USB memory key to the USB 
memory connector.
 
No file!
 
The specified data does not exist in USB memory key.
 
USB Memory Full
 
The USB memory key does not have sufficient 
free space.
Delete unneeded data.
 
Broken Data!!
 
The saved data is damaged.
 
Decrease the number of 
wav files.
 
The speed of access to USB memory key has 
slowed down because the number of files has 
increased.
Decrease the number of files.
 
Check USB memory!
 
The USB memory key is not operating correctly.
Check the USB memory key.
 
Remove the USB device!
 
Either a USB device not usable by the TD-9 is 
connected, or foreign matter has entered the 
USB memory connector, causing a short.
Immediately disconnect the device, and check 
that no foreign matter has entered the USB 
memory connector.
 
QUICK REC-related error messages
 
Memory Full!
 
No more memory capacity for Quick Rec.
Save your recording data on the USB memory 
key, and then start further recording.
 
System-related error messages
 
Unknown System Error
 
A problem has occurred with the internal sys-
tem.
Contact your dealer or a nearby Roland ser-
vice center.
TD-9_e.book 64 ページ 2008年1月23日 水曜日 午後4時24分