Emerson 2468CD Manuale Utente

Pagina di 186
Hydrastep 2468CB and 2468CD Manual 
Introduction to the Hydrastep 2468 Electronic Gauging System 
24685034
 
1-7 
1.4 
HYDRASTEP 2468 UPGRADE PATHS AND AVAILABLE 
OPTIONS 
Table 1.1 describes the available versions of the Hydrastep 2468 Electronic Gauging System 
and their possible options. 
Existing System 
Available Options 
Comments 
Description Part 
No. 
 
2468 CA  or     
2468 CC 
 
16 point EGS with 
local display 
 
Single power 
supply. 
Relay output board 
 
Time delay relay 
output board 
 
Opto-isolated 
output board 
 
Remote display 
unit 
 
Input board 
upgrade (ac) 
 
 
 
Input board 
upgrade (dc) 
24680504C 
 
24680509B 
 
 
24680505A 
 
 
24683B, C, or D 
 
 
24680501C 
 
 
 
 
24680516B 

}   
} Up to two boards (of any one
} type) can be fitted. 


 
 
Up to 6 can be used 
 
 
Provides an additional power 
supply (ac mains source) and 
16 point input circuit. Upgrades 
2468CA to 2468CB. 
 
Provides an additional power 
supply (24V dc source) and 16 
point input circuit. Upgrades 
2468CC to 2468CD. 
 
2468 CB  or     
2468 CD 
 
32 point EGS with 
local display 
 
Dual power supply. 
Relay output board 
 
Time delay relay 
output board 
 
Opto-isolated 
output board 
 
Remote display 
unit 
24680504C 
 
24680509B 
 
 
24680505A 
 
 
24683B, C, or D 
 

}   
} Up to four boards (of any one
} type) can be fitted. 


 
 
Up to 6 can be used 
 
 
Note:  If required, a 24680501C board can be fitted to a 2468CC (or a 24680516B board 
can be fitted to a 2468CA) to upgrade to a 2468CE.  The 2468CE is a 32 point 
Electronic Gauging System (EGS) with one ac mains source power supply and one 
24Vdc source power supply. 
    Table 1.1 - Upgrade paths and available options