Grizzly g0669X Manuale Utente

Pagina di 76
-26-
g0669X precision 10" x 54" Vs Milling Machine
Longitudinal Power feed System
your  mill  is  equipped  with  a  longitudinal  power 
feed  and  limit  switch  for  controlled  X-axis  table 
movement.  refer  to 
figure  27  and  the  descrip-
tions below to understand the functions of these 
devices.
A.  Limit  Switch:  stops  powered  table  move-
ment when either limit stop presses a plunger 
on the switch.
b.  Limit Stop: activates the limit switch. secure 
these devices along the table in the required 
positions.
C.  Rapid  Movement  button:  When  pressed, 
moves the table at the maximum speed in the 
direction selected.
D.  Direction Lever: starts, reverses, and stops 
longitudinal table movement.
E.  Speed Dial: Controls the speed that the table 
moves—turn  the  dial  clockwise  to  increase 
the speed.
f.  ON/Off  Switch:  the  master  power  switch 
for the power feed.
G.  Power Lamp: Lights when the power feed is 
turned 
ON.
H.  ball Handle: Manually positions the table.
I.  Graduated  Dial:  Marked  in  0.001"  incre-
ments,  each  complete  revolution  is  equal  to 
0.200" of longitudinal table travel.
Stay  away  from  the  spinning  longitudinal 
ball  handles  when  using  the  power  feed  to 
avoid entanglement and personal injury.
tools Needed 
Qty
Wrench 12mm ................................................... 1
to operate the longitudinal power feed:
1.  Loosen the table locks (see figure 28).
2.  position  the  limit  stops  along  the  table  to 
confine  the  longitudinal  distance  you  want 
the table to travel, then tighten the hex bolts 
to secure them in place.
3.  Move  the  power  feed  direction  lever  to  the 
center  or  neutral  position,  then  plug  the 
power feed power cord into one of the 110V 
outlets on the back of the electrical cabinet.
be  sure  there  is  enough  running  clearance 
between  the  table,  spindle,  vise/clamps,  or 
jigs  before  turning  the  power  feed  ON.  be 
aware  that  all  of  these  objects  represent 
potential pinch points.
figure 27. Longitudinal power feed system.
a
B
C
d
e
F
g
h
i
figure 28. table lock, limit switch, and limit stop.
Limit switch
Limit stop
table Lock