Grizzly Model G0638 Manuale Utente

Pagina di 60
-26-
G0637/G0638 Cyclone Dust Collector
9.  Secure the collection drum lids to the collec-
tion drums with the lid latches.
10.  Connect the dust collection drum assemblies 
to  the  funnel  port  with  the  9"  flexible  ducts 
and 9" duct clamps (see 
Figure 38).
Figure 38. Dust collection drum assemblies 
connected to funnel port.
Figure 40. Model G0638 control box bracket 
mounted.
Figure 39. Model G0637 control box mounted.
Figure 41. Model G0638 control box mounted.
 
Note:  The  remote  control  uses  IR  (infrared) 
to  communicate  with  the  control  box,  and 
must  have  direct  line-of-sight  to  the  control 
box. Locate the control box with this in mind.
Model G0638 Control Box
1.  Mount  the  control  bracket  onto  the  lower 
stand brace with (2) 
3
8
"-16 x 
3
4
" hex bolts, (4) 
3
8
" flat washers, and (2) 
3
8
"-16 hex nuts (see 
Figure 40).
2.  Open  the  control  box  and  identify  the  four 
mounting holes in the back of the cabinet.
3.  Attach the control box to the bracket already 
mounted on the stand brace with (4) M6-1 x 
15 Phillips head screws, (4) 6mm flat wash-
ers, and (4) M6-1 hex nuts (see 
Figure 41).
Model G0637 Control Box
1.  Mount  the  control  box  onto  the  lower  stand 
brace with (2) 
3
8
"-16 x 
3
4
" hex bolts, (4) 
3
8
" flat 
washers, and (2) 
3
8
"-16 hex nuts (see 
Figure 
39).