G0637/G0638 Cyclone Dust Collector
-35-
Always  guard  against 
static electrical build up 
by  grounding  all  dust 
collection lines.
We  also  recommend  wrapping  the  outside  of  all 
plastic ducts with bare copper wire to ground the 
outside of the system against static electrical build 
up.  Wire  connections  at  Y’s  and  T’s  should  be 
made with wire nuts.
Attach  the  bare  ground  wire  to  each  stationary 
woodworking  machine  and  attach  to  the  dust 
collector frame with a ground screw as shown in 
Figure 59. Ensure that each machine is continu-
ously grounded to the grounding terminal in your 
electric service panel.
Ensure that the entire system is grounded. If using 
plastic blast gates to direct air flow, the grounding 
wire  must  be  jumped  (
Figure  58)  around  the 
blast  gate  without  interruption  to  the  grounding 
system.
Figure 58. Ground jumper wire when using 
plastic blast gates and metal duct.
Copper 
Ground 
Wire
Metal Duct
Plastic 
Blast Gate
Figure 59. Flex-hose grounded to machine.
Flex-Hose
External Ground 
Wire
Internal 
Ground 
Wire
Ground Screw