Grizzly G0601 Manuale Utente

Pagina di 64
-16-
Model g0442/g0601 (Mfg since 8/10)
G0601 440v Conversion
the  Model  g0601  can  be  converted  for  440v 
operation.  this  conversion  job  consists  of  dis-
connecting  the  machine  from  the  power  source, 
replacing the control box assembly, and rewiring 
the motor for 440v operation. 
the  necessary  control  box  (part  p0601003-1) 
for  this  procedure  can  be  purchased  by  calling 
grizzly Customer service at (800) 523-4777.
All wiring changes must be inspected by a quali-
fied  electrician  before  the  machine  is  connected 
to the power source. if you need help at any time 
during this procedure, call grizzly tech support at 
(570) 546-9663.
To  rewire  the  Model  G0601  for  440v  opera-
tion:
1.  disConneCt MAChine FroM poWer!
2.  record  the  wire  colors  and  connections  of 
the  four  incoming  power  wires  and  the  four 
outgoing motor wires inside the 220v control 
box, as illustrated in 
figure 5. you can also 
refer to the 
G0601 Wiring Diagram on Page 
53 for a more complete wiring illustration.
1L1
3L2
5L3
NO13
2T1
4T2
6T3
NO14
98
97
96
95
GROUND
Overload Relay
Contactor
A1
 POWER SOURCE
figure 5. incoming and outgoing wire 
connections to the control box.
4 incoming
power Wires 
4 outgoing
Motor Wires
3.  disconnect  these  eight  wires,  then  replace 
the  220v  control  box  with  the  440v  control 
box.
4.  reconnect the wires as recorded in Step 2.
5.  rewire the motor as shown inside the motor 
junction cover.
 
Note: The reference wiring diagram on Page 
53  was  current  at  the  time  of  printing,  but 
always  use  the  wiring  diagram  provided 
inside the motor junction box, as it will reflect 
any  changes  to  the  motor  shipped  with  the 
machine.