Troubleshooting
symptom
possible Cause
possible solution
Machine does 
not start or a 
breaker trips.
1.  Wall fuse/circuit breaker is blown/tripped.
2.  power supply switched oFF or is at fault.
3.  Fuse has blown.
4.  hand-held remote controller is at fault.
5.  (g0442) start capacitor at fault.
6.  receiver is at fault.
7.  Motor connection wired incorrectly.
8.  thermal overload relay has tripped.
9.  Contactor  not  getting  energized/has 
burnt contacts.
10. Wiring is open/has high resistance.
11. Motor start switch or on/oFF button is 
at fault.
12. Circuit board is at fault.
13. Motor is at fault.
1.  ensure circuit size is suitable for this machine; 
replace weak breaker.
2.  ensure  power  supply  is  switched  on;  ensure 
power supply has the correct voltage.
3.  Correct short/replace fuse in control box.
4.  replace  batteries  in  hand-held  remote 
controller; stay in line-of-sight view and signal 
range.
5.  replace start capacitor.
6.  inspect receiver computer board; replace if faulty.
7.  Correct motor wiring connections (
Pages 52 & 53).
8.  turn cut-out dial to increase working amps and 
push the reset pin. replace if tripped multiple 
times (weak relay).
9.  test  for  power  on  all  legs  and  contactor 
operation. replace unit if faulty.
10. Check  for  broken  wires  or  disconnected/
corroded  connections,  and  repair/replace  as 
necessary. 
11. replace faulty on button or on/oFF switch.
12. inspect circuit board; replace if faulty.
13. test/repair/replace.
Machine has 
vibration or 
noisy operation.
1.  Motor or component is loose.
2.  Machine is incorrectly mounted or sits 
unevenly.
3.  Motor fan is rubbing on fan cover.
4.  Motor bearings are at fault.
1.  inspect/replace  stripped  or  damaged  bolts/
nuts, and re-tighten with thread locking fluid.
2.  tighten/replace anchor studs in floor; relocate/
shim machine.
3.  replace  dented  fan  cover;  replace  loose/
damaged fan.
4.  test by rotating shaft; rotational grinding/loose 
shaft requires bearing replacement.