model g0710 dust Collector (mfg. since 6/10+)
section 2: poWer supply
availability
Before installing the machine, consider the avail-
ability and proximity of the required power supply 
circuit.  If  an  existing  circuit  does  not  meet  the 
requirements for this machine, a new circuit must 
be  installed.  To  minimize  the  risk  of  electrocu-
tion, fire, or equipment damage, installation work 
and electrical wiring must be done by a qualified 
electrician in accordance with all applicable codes 
and standards.
Electrocution,  fire,  or 
equipment  damage  may 
occur  if  machine  is  not 
correctly  grounded  and 
connected  to  the  power 
supply.
full-load current rating
The  full-load  current  rating  is  the  amperage  a 
machine draws at 100% of the rated output power. 
On  machines  with  multiple  motors,  this  is  the 
amperage drawn by the largest motor or sum of all 
motors  and  electrical  devices  that  might  operate 
at one time during normal operations.
full-load current rating at 110v ...... 14 amps
full-load current rating at 220v ....... 7 amps
The full-load current is not the maximum amount 
of amps that the machine will draw. If the machine 
is overloaded, it will draw additional amps beyond 
the full-load rating.
If the machine is overloaded for a sufficient length 
of time, damage, overheating, or fire may result—
especially  if  connected  to  an  undersized  circuit. 
To  reduce  the  risk  of  these  hazards,  avoid  over-
loading  the  machine  during  operation  and  make 
sure it is connected to a power supply circuit that 
meets the requirements in the following section.
For  your  own  safety  and  protection  of 
property,  consult  a  qualified  electrician  if 
you  are  unsure  about  wiring  practices  or 
electrical codes in your area.
Note: The circuit requirements listed in this man-
ual apply to a dedicated circuit—where only one 
machine will be running at a time. If this machine 
will  be  connected  to  a  shared  circuit  where  mul-
tiple  machines  will  be  running  at  the  same  time, 
consult  a  qualified  electrician  to  ensure  that  the 
circuit is properly sized for safe operation.
A power supply circuit includes all electrical equip-
ment between the main breaker box or fuse panel 
in your building and the incoming power connec-
tions at the machine. This circuit must be sized to 
safely handle the full-load current drawn from the 
machine for an extended period of time.
circuit information
circuit requirements for 220v
nominal voltage .............................. 220v/240v
cycle ..........................................................60 hz
phase ........................................... single-phase
circuit rating ...................................... 15 amps
plug/receptacle ............................. nema 6-15
This  machine  can  be  converted  to  operate  on  a 
220V power supply. To do this, follow the 
Voltage 
Conversion instructions later in this section. The 
intended 220V circuit must have a verified ground 
and meet the requirements that follow:
This  machine  is  prewired  to  operate  on  a  110V 
power supply circuit that has a verified ground and 
meets the following requirements:
circuit requirements for 110v
nominal voltage ...............................110v/120v
cycle ..........................................................60 hz
phase ........................................... single-phase
circuit rating ...................................... 15 amps
plug/receptacle ............................. nema 5-15