Emulex 3.4 Manuale Utente

Pagina di 154
The HBAnyware Utility User Manual
Page 56
HardALPA=0x
HardALPA allows the HBA to use a hard assigned loop address. 
Value: 0x00 - 0xEF (hex) 
Default = 0x00 (use soft addressing, or flash stored hard address 
value) 
Note: Only valid AL_PAs may be used.
Reset 
InitTimeout=
Determines the number of time-out seconds during driver initialization 
for the link to come up. If the link fails to come up by InitTmeout, driver 
initialization exits but is still successful. If the link comes up before 
InitTimeout, the driver sets double the amount for discovery to 
complete. 
Value: 5 -30 seconds or 0x5 - 0x1E (hex)
Default = 15 seconds (0xF) 
Reboot 
LinkSpeed=n 
LinkSpeed has significance only if the HBA supports speeds other 
than one Gbit. 
If set to 0 = auto link speed detection.
If set to 1 = 1 Gbit.
If set to 2 = 2 Gbit.
If set to 4 = 4 Gbit.
If set to 8 = 8 Gbit.
Value: 0, 1, 2, 4 and 8
Default = 0 
Note: Setting this option incorrectly may cause the HBA to fail to 
initialize.
Reset 
LinkTimeOut=
LinkTimeOut applies to private loop only. A timer is started on all 
mapped targets using the link timeout value. If the timer expires 
before discovery is re-resolved, commands issued to timed out 
devices will end up returning a SELECTIION_TIMEOUT. The Storport 
driver will also be notified of a Bus change event which will lead to the 
removal of all LUNs on the timed out devices.
Value: 1 - 500 seconds or 0x0 - 0xFE (hex)
Default = 30 (0x1E) 
Dynamic 
Table 1: Storport Miniport Driver Parameters (Continued)
Parameter
Definitions
Activation 
Requirement