Emerson SZV22 Manuale Utente

Pagina di 40
 6 
2008SSD-34 
(5/08) 
Single-Compressor Module 
 
Installation
NOTE: Required Component – High Pressure Discharge Gas Bypass Valve
 To eliminate redundancy, the high pressure discharge gas bypass (recycle) valve was removed from some of the 
scroll modules (see table below). Packagers will need to install downstream pressure relief of our module.
2.3 
Ambient Temperature Range
The Compressor Module operating ambient temperature is 20°F to +122°F (-29° to +50°C). For details on 
ambient temperatures for VFD startup and Compressor Module operation, see Table 10 on page 29.
Model
Max 
Delivery 
Pressure 
(PSIG)
Max 
Flow 
(MCFD)
Drive 
HP
High 
Press 
Switch 
Setting 
(PSIG)
Low 
Press 
Switch 
Setting
High 
Temp 
Setting
°F (°C)
Oil 
Thermal 
Bypass 
Valve 
Setpoint
 °F (°C)
Gas 
Bypass 
Valve
Module 
Weight 
(Lbs.)
Single Scroll Units
SZO22C3A-EDE-234
125
100
10
215
2” W.C.
(5 mbarg)
240
(116)
200
YES
350
SZV22C1A-EDE-140
190
100
15
215
2” W.C.
(5 mbarg)
280
(138)
250
NO
356