POWER SUPPLY
CONNECTING THE COMPRESSOR TO THE POWER SUPPLY:
To eliminate the possibility of an electric shock your machine has been fitted with a 
BS approved, non rewireable moulded plug and cable which incorporates a fuse, the 
value of which is indicated on the pin face of the plug. Should the fuse need to be 
replaced an 
 approved BS1362 fuse must be used of the same rating, marked thus
. The fuse cover is detachable, never use the plug with the cover omitted. If a 
replacement fuse cover is required, ensure it is of the same colour as that visible on the 
pin face of the plug (i.e. red). Fuse covers are available from your Draper Tools stockist.
If the fitted plug is not suitable, it should be cut off and destroyed. *The end of the 
cable should now be suitably prepared and the correct type of plug fitted. See below.
*WARNING:
A plug with bare flexible wires exposed is hazardous if engaged in a live power socket 
outlet.
WARNING: THIS APPLIANCE MUST BE EARTHED.
Green and Yellow - Earth, Blue - Neutral, Brown - Live.
As these colours may not correspond with the coloured markings identifying the 
terminals in your plug, proceed as follows.:
The wire which is coloured green and yellow must be connected to the terminal in the 
plug which is marked with the letter 'E' or by the earth symbol
or coloured green or 
green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked 
with the letter 'N' or coloured black or blue.
The wire which is coloured brown must be connected to the terminal which is marked 
with the letter 'L' or coloured red or brown.
N.B. Three phase machines must be connected by a qualified electrician.
CONNECTING YOUR MACHINE TO THE POWER SUPPLY (110V)
To eliminate the possibility of an electric shock your machine has been fitted with a 
BS approved, rewireable plug and cable. If the fitted plug is not suitable, it should be 
removed, the end of the cable should be suitably prepared and the correct type of plug 
fitted. See below.
WARNING: THIS APPLIANCE IS DOUBLE INSULATED.
Single phase 110 volt machines must be connected using the relevant coding and 
matching the colour of the flexible cable to that of the plug. The procedure is as follows:
1. Connect brown coloured core to plug terminal marked letter ‘L’ (live).
2. Connect blue colour core to plug terminal marked letter ‘N’ (neutral).
EXTENSION LEAD CHART:
Extension lead sizes shown assure a voltage drop of not more than 5% at rated 
load of tool.
 
Ampere rating
 
 
3 6 10 
13
 
(on Name plate)
 
7.5m 0.75 
0.75 
1.0 
1.25
 
15m 0.75 
0.75 
1.0 
1.5
 
22.5m 0.75 
0.75 
1.0 
1.5
 
30m 0.75 
0.75 
1.25 
1.5
 
45m 0.75 
1.25 
1.5 
2.5
Extension Cable Length
Wire Size mm2
 