Curtis OL 812 Manuale Utente

Pagina di 52
 
 
 
 
CAP-215 
15 
 
Instruction Manual Oil-Less Compressors
 
 
 
3.2. 
FUNCTIONAL DESCRIPTION OF FINAL SEPARATOR 
 
 
A final separator is mounted after the three first stages of the single-stage oil-less compressor and after the 
 
second  stage of the 2-stage oil-less compressor. 
 
 
Separation is achieved by means of centrifugal action provided by a baffle (4).  A sintered metal filter (2) is 
 
provided additionally to remove dirt contamination. 
 
3.2.1. CONDENSATE 
DRAIN 
 
 
1-stage compressor (option)
 
 
The condensate has to be drained manually every 15 minutes during operation and after each operation.  At 
 
increased humidity, intervals for draining may be shorter.  Therefore open knurled nut mounted on lower part of 
 
separator housing.  After draining the condensate, firmly tighten knurled nut. 
 
 
Compressors equipped with a condensate drain valve are drained automatically.  Ensure that the filters are 
 
drained every 15 minutes.  At increased humidity, intervals for draining may be shorter. 
 
 
2-stage compressor (std.) 
 
 
The condensate has to be drained manually every 15 minutes during operation and after each operation.  At 
 
increased humidity, intervals for draining may be shorter.  Therefore open knurled nut mounted at the lower part 
 
of separator housing.  After draining the condensate, firmly tighten knurled nut. 
 
 
Compressors which are equipped with a condensate drain valve are drained automatically.  Ensure that the filters 
 
are drained every 15 minutes.  At increased humidity, intervals for draining may be shorter. 
 
3.2.2.  FINAL SEPARATOR MAINTENANCE 
 
 
Maintenance process is the same as for intermediate separator, see chapter 3.1.2.