Grizzly G9953ZXF Manuale Utente
-10-
Ultimate Series Jointers
Rewire To 440V
(G9953ZXF Only)
To rewire the Model G9953ZXF to 440V:
1.
Disconnect the sander from the power
source!
source!
2.
Replace the power indicator light in the
pedestal switch to one suitable for 440V
operation
pedestal switch to one suitable for 440V
operation
3.
Remove the RHN-18 overload relay and
replace it with a RHN-10 (5.5-8.5A) type, with
the dial set to 7A (
replace it with a RHN-10 (5.5-8.5A) type, with
the dial set to 7A (
Figure 4).
4.
Remove the CN-18 magnetic contact over-
load relay and replace it with a CN-11 type
(
load relay and replace it with a CN-11 type
(
Figure 5).
5.
Wire the motor as shown on the diagram on
the inside of the motor wire cover. Note—
The circled references on the diagrams rep-
resent labels on the wires. Also, Figure 6
below has been provided for your reference
and are current at the time that this manual is
being written. However, always use the dia-
gram on the wire cover that comes with your
motor!
the inside of the motor wire cover. Note—
The circled references on the diagrams rep-
resent labels on the wires. Also, Figure 6
below has been provided for your reference
and are current at the time that this manual is
being written. However, always use the dia-
gram on the wire cover that comes with your
motor!
Figure 4. Overload relays.
7
RHN-10
Overload Relay
Figure 5. Overload relays.
11
Figure 6. 440V motor wiring.
G9953ZXF
Motor Wiring
R
S
T
R
S
T
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
220V
440V
CN-11
Magnetic
Contactor
Overload
Relay