Tektronix TDS460A Manuale Utente
Command Descriptions
TDS Family Oscilloscope Programmer Manual
2–301
TRIGger:MAIn:LOGIc:STATE:WHEn
Not on TDS 400A
Sets or queries the main logic state trigger.
Trigger
TRIGger:MAIn:LOGIc:STATE:WHEn { TRUe| FALSe}
TRIGger:MAIn:LOGIc:STATE:WHEn?
:
MAIn
TRIGger
LOGIc
:
:
STATE
<Space>
?
TRUe
FALSe
WHEn
:
TRUe specifies the trigger to occur when the condition is met on the fourth
channel and the pattern of the first three channels are at the desired states.
channel and the pattern of the first three channels are at the desired states.
FALSe
TRIGger:MAIn:LOGIc:THReshold? (Query Only)
Not on TDS 400A
Returns the main logic trigger threshold voltage for all channels.
Trigger
TRIGger:MAIn:LOGIc:THReshold?
THReshold
TRIGger
:
:
LOGIc
MAIn
:
?
TRIGGER:MAIN:LOGIC:THRESHOLD?
might return
might return
:TRIGGER:MAIN:LOGIC:THRESHOLD:CH1 0;CH2 0;
CH3 0;CH4 0
Group
Syntax
Arguments
Group
Syntax
Examples