IBM EGX-600 Manuale Utente
![IBM](https://files.manualsbrain.com/attachments/f70d337d03c66895b7a6fbe0e6de3554f47d7dd3/common/fit/150/50/fb4e568062ca4d0154259807170f4c71f2c7aafa861a4d9a0eb3af958af4/brand_logo.png)
39
Chapter 3 - Preparations
3-2. Cutter Installation Method 1 (With Nose Unit)
2. Nose-unit Installation and Menu Settings
5
Install the nose unit. Tighten fully, then loosen
two turns.
two turns.
6
Fully loosen the lock nut.
7
Use the menus to set [AUTO Z CONTROL] to ON.
(1) Press
several times to display the screen shown at right.
(2) Press
to move the blinking cursor to [OTHERS], then press
.
(3) Press
several times to display the screen shown at right.
(4) Press
to move the blinking cursor to [ON], then press
.
8
Use the menu to set [REVOLUTION] to ON.
(1) Press
several times to display the screen shown at right.
(2) Press
to move the blinking cursor to [OTHERS], then press
.
(3) Press
to move the blinking cursor to [ON], then press
.
9
Press
several times to return to the top screen.
Be sure to loosen the lock nut.
X 0 Y 0
Z 0 8000RPM
Z 0 8000RPM
I/O
O
THERS
TEACHING SELF
REVOLUTION
<ON> OFF
<ON> OFF
AUTO Z CONTROL
<ON> OFF
<ON> OFF
I/O
O
THERS
TEACHING SELF