Grizzly G9749 Manuale Utente

Pagina di 44
G9749 Variable Speed Drill Press
-9-
Serious  personal  injury  could  occur  if  you 
connect  the  machine  to  the  power  source 
before  you  have  completed  the  setup  pro-
cess.  DO  NOT  connect  the  machine  to  the 
power source until instructed to do so.
110/220V Operation
SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The  Model  G9749  features  a  110/220V  motor 
that is prewired for 220V and draws the following 
amps under maximum load:
Motor Draw at 110V .............................. 16 Amps
Motor Draw at 220V ............................... 8 Amps
Circuit Requirements
We  recommend  connecting  your  machine  to  a 
dedicated  and  grounded  circuit  that  is  rated  for 
the amperage given below. Never replace a circuit 
breaker  on  an  existing  circuit  with  one  of  higher 
amperage  without  consulting  a  qualified  electri-
cian  to  ensure  compliance  with  wiring  codes. 
If 
you are unsure about the wiring codes in your 
area or you plan to connect your machine to a 
shared circuit, consult a qualified electrician.
110V Circuit ...........................................30 Amps
220V Circuit ...........................................20 Amps
Plug/Receptacle Type
We recommend using one of the following plugs 
for your machine on a dedicated circuit only (see 
Figures 3 & 4 for examples):
110V Plug & Receptacle ............................ L5-30
220V Plug (provided) & Receptacle .............6-15
Figure 4. 6-15 plug and receptacle.
Figure 3. L5-30 plug and receptacle.
NOTICE
The Model G9749 is prewired for 220V oper-
ation.  If  you  plan  to  rewire  your  machine 
for  110V,  you  must  change  the  motor  wir-
ing,  plug,  and  power  receptacle.  Consult 
a qualified electrician before attempting to 
rewire your machine!