Grizzly G9749 Manuale Utente

Pagina di 44
-28-
G9749 Variable Speed Drill Press 
Symptom
Possible Cause
Possible Solution
Machine vibrates 
excessively or is unusually 
noisy.
1.  Motor fan is rubbing on fan cover.
2.  Motor or component is loose.
3.  Belt is slapping belt housing.
4.  V-belt is worn.
5.  Pulley is loose.
6.  Machine  is  incorrectly  mounted 
to  the  stand,  stand  is  incorrectly 
mounted to the floor, or the stand is 
uneven.
7.  Chuck or cutter is at fault.
8.  Motor bearings are at fault.
9.  Spindle bearings at fault.
1.  Replace/repair dented fan cover, and replace loose 
or damaged fan.
2.  Replace  component  fasteners  and  re-tighten  with 
thread locking fluid.
3.  Replace, realign, or re-tension belt.
4.  Replace belt.
5.  Remove  pulley,  replace  with  key  as  required,  and 
re-install securely.
6.  Make  sure  the  mounting  hardware  is  tight;  place 
shims under machine.
7.  Replace  out-of-round  chuck,  replace  or  resharpen 
cutter, use appropriate feed rate and cutting RPM.
8.  Check  bearings,  replace  motor  or  bearings  as 
required.
9.  Replace bearings.
Symptom
Possible Cause
Possible Solution
Drilling stops, but the motor 
still operates.
1.  The belt is loose, worn, or broken.
2.  Bit slips in chuck.
3.   Pully slips on shaft.
1.  Replace, realign, or re-tension belt.
2.  Tighten bit; inspect bit for burrs or other obstructions 
that might interfere with clamping surface.
3.  Remount or replace pully and shaft.
The  chuck  wobbles  or  is 
loose on the spindle shaft. 
1.  Foreign  material  is  stuck  between 
the  chuck-to-spindle  mating  sur-
face.
2.  Damaged chuck.
1.  Remove the chuck, clean, and de-burr the tapered 
chuck  and  spindle  mating  surfaces,  then  reas-
semble.
2.  Replace.
The spindle does not retract 
completely  in  the  upper-
most position or it binds.
1.  The quill shaft is gummy with saw-
dust and oil.
2.  The  quill  lock  is  locked  or  not  fully 
released.
3.  The  feed  shaft  return  spring  is 
weak.
1.  Clean shaft and lubricate with a light coat of oil.
2.  Fully release the quill lock.
3.  Replace the feed shaft return spring.
The  quill  has  excessive 
deflection.
1.  The quill bearings are worn or dam-
aged.
2.  The quill shaft is at fault.
1.  Replace the bearings.
2.  Replace the quill shaft.
Drill bit wobbles, holes are 
oversized.
1.  Drill bit installed incorrectly.
1.  Remove drill bit and reinstall. 
Drill Operations