AR-CF2  TROUBLESHOOTING  8 - 2
Problem
Tray alarm is displayed on the system display. 
Case1
Cause
Sub-tray pulling detection sensor fault 
Check and 
remedy
Measure a voltage on TP14 on the 
controller PCB and check that 5 V is 
observed when the sub-tray is in place, 
and that 1 V or less is observed when the 
sub-tray is pulled out. Replace the sensor 
if the measured voltage exceeds these 
ranges.
Case2
Cause 
Sub-tray pulling detection sensor fault
Check and 
remedy
Measure a voltage of TP15 on the 
controller PCB and check that 5 V is 
observed when the tray is in place, and 
that 1 V or less is observed when the tray 
is pulled. Replace the sensor if the 
measured voltage exceeds these ranges.
Case3
Cause 
Controller PCB fault
Check and 
remedy
If the problem is not solved by a change in 
the sensor level after the above cases 1 
and 2 are confirmed, replace the 
controller PCB.
Problem
Cover open is displayed on the system display. 
Case1
Cause
JAM cover open/close switch fault 
Check and 
remedy
Check continuity between the switch 
contacts., Replace the switch if no 
conduction is measured. 
Case2
Cause
Reverse unit open/close sensor fault
Check and 
remedy
Measure a voltage of TP9 on the 
controller PCB and check that 1 V or less 
is observed when the reverse unit is 
open, and that 5 V is observed when the 
reverse unit is closed. Replace the sensor 
if the measured voltage exceeds these 
ranges.
Case3
Cause
Rack cover open/close sensor fault 
Check and 
remedy
Measure the voltage of TP10 on the 
control PWB and check that it is 1V or 
less when the base cover is opened and 
5V when closed.
If the voltage is outside the above 
specifications, replace the sensor with a 
new one.
Case4
Cause
Controller PCB fault
Check and 
remedy
If the problem is not solved by a change 
in the sensor level after the above cases 
1 to 3 are confirmed, replace the 
controller PCB.
Problem
Inserter unset is displayed on the system display.
Case1
Cause
Set sensor fault
Check and 
remedy
Measure a voltage of TP16 on the 
controller PCB and check that 5 V is 
observed when the inserter is set, and 
that 1 V or less is observed when the 
inserter is not set. Replace the sensor if 
the measured voltage exceeds these 
ranges.
Case2
Cause
Controller PCB fault
Check and 
remedy
If the problem is not solved by a change 
in the sensor level after the above case 1 
is confirmed, replace the controller PCB.
1
Problem 
The registration clutch does not perform.
Case1
Cause
Loose contact of the clutch connector 
terminal 
Check and 
remedy
Check continuity of the connector 
contacts. (CN4) 
Case2
Cause
Disconnection of the clutch coils 
Check and 
remedy
Inspect the coils for continuity. Replace 
the coils if no continuity is measured. 
Case3
Cause
Controller PCB fault 
Check and 
remedy
If the clutch does not perform in the clutch 
single operation mode, replace the 