Roland VP-770 Manuale Utente

Pagina di 128
97
This section explains the functions the diff erent system parameters have, as well as the composition of 
these parameters. 
For details on how to make settings, refer to “System Settings” (p. 95).
 
SYSTEM MIDI
Here you can make settings for MIDI transmission and reception.
Parameter
Value
Description
Regist Ctrl Ch
Ch1–Ch16,
OFF
Registration Control Channel selects the MIDI receive channel used during switching
of registrations when MIDI messages (Program Change/Bank Select) are sent from an 
external MIDI device. Set this to “OFF” if registrations are not to be switched from an 
external MIDI device.
Rx Program Change
ON, OFF
Specifi es whether Program Change messages will be received (ON) or not (OFF).
Rx Bank Select
ON, OFF
Specifi es whether Bank Select messages will be received (ON) or not (OFF).
Rx Control Change
ON, OFF
Specifi es whether Control Change messages will be received (ON) or not (OFF).
Rx SysEx
ON, OFF
Specifi es whether System Exclusive messages will be received (ON) or not (OFF).
Ens Rx Ch
Ch1–Ch16
Specifi es the receive channel on which the Ensemble part will receive MIDI messages.
Voc Rx Ch
Ch1–Ch16
Specifi es the receive channel on which the Vocal Designer part will receive MIDI 
messages.
B&P Rx Ch
Ch1–Ch16
Specifi es the receive channel on which the Bass & Percussion parts will receive MIDI
messages.
Tx Edit
ON, OFF
Specifi es whether changes you make to the settings of each part will be transmitted as
system exclusive messages (ON) or not transmitted (OFF).
Tx Program Change
ON, OFF
Specifi es whether Program Change messages will be transmitted (ON) or not (OFF).
Tx Bank Select
ON, OFF
Specifi es whether Bank Select messages will be transmitted (ON) or not (OFF).
Local Sw
ON, OFF
Specifi es whether the VP-770’s keyboard will play the sounds of each of the VP-770’s 
parts (ON) or will not play them (OFF).
Normally, you can leave this ON.
Performance data from the VP-770’s keyboard will be sent to each of the VP-770’s parts
and transmitted from the MIDI OUT connector. If you have connected an external MIDI 
sequencer, the MIDI messages transmitted from the MIDI OUT connector will be routed
through your MIDI sequencer and returned to the VP-770’s MIDI IN connector. This can
create problems, such as duplicate MIDI messages being received, which causes each of 
the VP-770’s parts to sound every note twice. In this situation, you can turn the Local Sw 
setting OFF so that the performance data from the keyboard will not play the parts.
Tx Active Sens
ON, OFF
Specifi es whether Active Sensing messages will be transmitted (ON) or not (OFF).
Soft Through
ON, OFF
Thru function re-transmits all messages received at the MIDI IN connector to the MIDI 
OUT connector without modifying them in any way.
Device ID
17–32
When you want to transmit or receive System Exclusive messages, set this parameter to 
match the Device ID number of the other MIDI device.
SysEx Protect
ON, OFF
This prevents the settings of user memory from being rewritten by system exclusive 
messages transmitted by an external MIDI device. The “ON” setting prevents rewriting,
and the “OFF” setting allows rewriting.
 System  Parameters