Planar LC12 Manuale Utente
Title: Product Specification: LC12 High-Bright Monitor
Page 8 of 24
Document Number: 023-0284-01
Revision: A
Power spectrum is referenced per MIL STD 810 E Environmental Test Method 505.3, Table -II
Spectral Energy Distribution and permitted tolerances
Maximum solar power flux = 1120 watts/m
2
at 65 degrees normal to the Monitor surface.
These values assume no solar radiation attenuation from the customer-supplied vandal shield.
3.3 Altitude
Maximum operating altitude is 3,000 meters [9,850 feet]. Maximum shipping and storage
altitude is 12,000 meters [39,400 feet].
altitude is 12,000 meters [39,400 feet].
3.4 Mechanical Vibration and Shock
Note: Tests performed with unpackaged Monitors are mounted in a Planar approved rigid
retaining fixture.
3.4.1
Vibration
Non-Operating (sinusoidal):
10-200 Hz, 0.9g acceleration, 120 seconds per
sweep for 15 minutes, three axes, (x, y, z).
Following exposure unit shall meet all
Following exposure unit shall meet all
performance requirements.
Non-operating (random):
10-200 Hz, 0.02g
2
/Hz, 10 min/axis, three (x, y, z).
Following exposure unit shall meet all
performance requirements.
3.4.2
Shock
Non-operating:
30 g, > 2.5 ms duration, ½ sine, 1 shocks per axis.
Following exposure unit shall meet all
Following exposure unit shall meet all
performance requirements.
3.4.3
Shock Packaged Product
Non-operating:
30 inch free fall or simulated drop, 1 drop per side, 6
sides and 1 drop per edge, 3 edges 1 shocks per axis.
sides and 1 drop per edge, 3 edges 1 shocks per axis.
With accelerometer attached to center of product
display screen, a maximum of 50 G’s is allowed.
display screen, a maximum of 50 G’s is allowed.
Following exposure unit shall meet all performance
requirements.
Y (rear)
X (side)
Z (bottom)
DISPLAY
Figure 3. Monitor unit orientation 1